Internet Windows Android

Intelligent thermostat Zont GSM-Climate H1 - room temperature monitoring, remote control of the heating boiler, alarm notification, internet service. ZONT - H Thermostats for remote control of the boiler Umbrella H1 online login

A large number of materials on the network are devoted to setting up the ZONT EVAN H-1 GSM modem. This article is devoted to setting up an analogue called ZONT H-1 V, in a modular design for a DIN rail. made in a gray plastic case, removable top cover with logo image. The connectors are located at the bottom.

The kit includes a modular power supply also for mounting on a DIN rail. There is no power cord with a plug. The output is 12 Volts DC. Power is connected to 9 and 7 pins, do not confuse polarity!

The protective cover of the modem is removed using a miniature flat screwdriver, under it is a slot for a SIM card, LEDs and a jumper for turning on the battery. The function of the LEDs is the same as in

The passport indicates the purpose of the contacts in the connector. I would like to draw your attention to the fact that in the passport - an error: normally closed contact - number 3, not 2, as indicated in the passport. We are convinced of this by measuring the resistance between the contacts.

When the yellow LED is on (the boiler is running) - contacts 1 and 2 are closed. That is, the 2nd contact is normally open. We connect all gas boilers with a jumper in the thermostat circuit to contacts 1-2 of the GSM modem (remove the jumper beforehand).

We connect the temperature sensor in accordance with the diagram in the passport for 4 and 6 contacts. Do not confuse polarity!

The modem kit also includes a 220 / 12V converter to bring the 220 Volt alarm signal to an acceptable 12 Volt value. Such voltage can be safely applied to input "8" of the GSM modem.

The modem settings in your ZONT-ONLINE personal account do not differ from the modem settings.

Additional technical advice can be obtained online, for this fill out Technical support application form.

"ZONT H-1" is a module for remote monitoring and control of a heating boiler. Configuration and control are carried out via the GSM channel and via the Internet. In accordance with the set parameters, it automatically regulates the operation of the boiler in heating mode to maintain the desired temperature in the room. Also, the device can monitor the technical condition of the boiler and signal a malfunction in the event of an emergency or power outage.

Why you should buy "ZONT H-1"

  • Control from your phone, tablet or computer. The thermostat commands can be transmitted from any phone, tablet or PC. For the convenience of work, there are free applications for the phone and a personal account on the site. To protect against unauthorized access, the entrance to your personal account is password protected.
  • Individual setting of operating modes. It is possible to preset several modes of heating the house in order to select the desired mode at the moment with one movement.
  • 10 temperature sensors for any purpose. The thermostat can simultaneously connect 10 temperature sensors (wired or radio sensors). The indications of the main are used to control the operation of the boiler. An additional one is assigned to it in reserve. If the main thermostat fails, it automatically switches to work by the backup sensor and the boiler control does not stop. The readings of the remaining sensors are used for general monitoring of the heating system.
  • Alert system for all occasions. The thermostat controls the temperature in the house and outside, the supply voltage, the technical condition of the boiler and much more. If the values ​​deviate from the specified ones, he informs you about this by calling or SMS-message.
  • Easy installation, no special skills required. Easily connects to an electric or gas boiler instead of a room thermostat. A SIM card of any operator that provides stable reception is inserted into the device, and the supply voltage is supplied. You need to send an SMS from the owner's phone to the SIM card number and "introduce" the device.

Possibilities of the GSM module "ZONT H1"

  • Through the free WEB interface, the following options are provided: real-time display of the current state of the boiler and room temperature, control of the boiler operation mode, monitoring of temperatures (inside, outside the room, heat carrier) for any selected period of time, programming the boiler operation according to a weekly schedule, displaying notifications about triggering of additionally installed sensors.
  • Remote control of the boiler operation can be carried out by SMS, dialing to the voice menu, via the Internet (WEB-interface and mobile application for Android and iOS devices).
  • Notification of events: deviation of the measured temperature from the preset threshold values, boiler failure (provided that the thermostat is connected to the boiler emergency output), temperature sensor failure and thermostat transition to emergency operation mode, loss / restoration of power supply (mains) (only with a backup battery installed) ...
  • Using the module for GSM security - monitoring the status of additional sensors (security or water / gas leakage) connected to the "Alarm" input of the thermostat.
  • Event memory: a diary of measured temperatures for any period without a limitation period, date and time of the boiler failure detection, date and time of the change in the boiler and thermostat operation mode, a list of executed control commands via the voice menu, sent SMS, software updates, date and time of disappearance / restoration power supply (network).
  • Remote software update without shutting down the module itself and dismantling it.

For which boilers is the "ZONT H-1" GSM thermostat suitable?

The ZONT H-1 module is, in fact, a simple room thermostat, but only made on a hardware platform using GSM / GPRS modem and WEB technology. The principle of its operation and the method of connection to any gas or electric boiler is exactly the same as that of conventional thermostats. It connects to the connector for the room regulator and controls the boiler, maintaining the set temperature according to the readings of its temperature sensor. For this, the thermostat switches the boiler on or off by closing the contacts of its output relay.

Thus, if your boiler provides the ability to control commands from a room thermostat, then the "ZONT H-1" thermostat can be used with it.

Specifications "ZONT H1"

Supply voltage 10-28V
Maximum current consumption 150 mA
Number of inputs 2
Dry contact output (make / break) 1
Type of connected wired temperature sensors DS 18S20
Type of connected radio-temperature sensors ML-703
The total number of simultaneously connected temperature sensors 10
Maximum permissible length of a loop with temperature sensors 100 m
Maximum current through relay contacts 1000 mA
Maximum voltage of switched relay contacts ~ 120 V, = 24 V
Voice interface there is
WEB interface there is
1-Wire interface there is
Operating temperature range from -30 to +55 ° С
Frequency bands of the GSM modem 800, 900, 1800, 1900 MHz
Data transmission channel GPRS
GSM antenna external
Internal non-volatile memory there is
Time to reach operating mode no more than 50 seconds
Average service life 7 years
dimensions 77 x 86 x 33 mm
Weight not more than 200 g
Body material ABC plastic

Delivery set "ZONT H-1"

  • Thermostat "GSM-Climate ZONT H-1".
  • Mounting base.
  • Power adapter from 220 V.
  • GSM antenna.
  • Wired thermal sensor.
  • Screw terminal blocks.
  • SIM card.
  • User guide.
  • Warranty card.
  • Branded packaging.

Boiler remote control unit ZONT H-1 GSM-Climate

  • Supply voltage 10-14 V
  • Maximum current consumption 150 mA
  • Maximum current through relay contacts 1000 mA
  • Frequency bands of GSM-modem 800, 900, 1800, 1900 MHz
  • Weight: 200g

ZONT H-1 GSM-Climate is a modern device for controlling a heating boiler via the Internet and telephone.

It automatically controls the operation of the boiler, monitors its technical condition and signals in the event of an emergency or power outage.

Comfortable temperature:

With the help of ZONT H-1 GSM-Climate, you can remotely change the parameters of the heating system and control the temperature in the room. In this case, it is possible to switch to the mode of fixed temperatures "Economy" or "Comfort", to make a weekly "Schedule" of the heating boiler or to turn it off remotely.
ZONT H-1 GSM-Climate independently monitors the readings of the digital air temperature sensor and adjusts the boiler operation depending on the set temperature parameters in the room.

Remote control:

ZONT H-1 GSM-Climate is a compact device with its own SIM card connected to a heating boiler. Commands to it can be transmitted from any phone (satellite, mobile or fixed line), tablet or PC. Remote control requires a unique password to prevent unauthorized access.

An additional "Alarm input" provides connection of an unlimited number of similar detectors: motion or opening sensors, fire and smoke alarms, water leakage or gas leakage sensors and other similar equipment. Information is transmitted via mobile communication channels and the Internet. You simply indicate in the system settings the necessary phone numbers for notification: your own or a security organization.

How does ZONT H-1 work in alarm mode?

The equipment is installed in the room, selected depending on the problem being solved, for example, sensors that react to movement. Such sensors detect the presence of strangers in the house and send a signal to the unit's GSM modem. An alarm notification is sent to the programmed phone numbers in the form of a voice call or SMS message, and is also displayed in the personal account of the online service. Thus, you can quickly make a decision to protect your property: call a police squad or just call your neighbors.

Of course, the main function of ZONT H-1 is to control the operation of the heating boiler. But you must admit that ensuring the safety of your home is a very useful feature of this "smart" device. Moreover, we are talking not only about protection from the penetration of unauthorized persons, but also from other risks: fire, water and gas leakage.That is, it is also a kind of insurance against everyday troubles.

Free WEB service:

  • Checking the health of an electric or gas boiler
  • Informing about an accident and a power failure
  • Control of boiler operating modes from the phone and via the Internet
  • Room temperature monitoring
  • Maintaining the temperature in the room according to an individual schedule
  • Notifications about triggering of the Alarm input sensors (GSM-signaling)
  • User-friendly interface and mobile apps for iOS and Android

Energy saving:

If you are at home only on weekends or in the evening / night time, the ZONT H-1 GSM-Climate control unit will maintain the minimum temperature in the house in your absence, saving energy resources, and upon returning, will create comfortable conditions in the house.

Functionality:

Free WEB interface:

  • constant connection with the server
  • recording and automatic transmission of accumulated information
  • boiler status display:
    • current operating mode
    • room temperature
    • emergency mode indication
  • changing the boiler operating mode "in one click"
  • temperature monitoring for any period of time
  • weekly schedule editor for temperature control
  • notifications about activation of additional sensors (Alarm input)

Boiler operation control:

  • SMS commands
  • dialing to the voice menu
  • through the Internet

Event notification:

  • change in t below the set threshold
  • change in t above the set threshold
  • boiler failure
  • temperature sensor malfunction
  • loss and appearance of supply voltage
  • triggering of the "Alarm Input" sensors

Event memory:

  • room temperature values ​​at any given time
  • date and time of boiler failure
  • date and time of changing the operating mode
  • executed commands of the voice menu
  • sent SMS
  • date and time of software update
  • date and time of power on / off

Specifications:

Supply voltage 10-14V
Maximum current consumption 150 mA
One analog input Yes
One dry contact output (make / break) Yes
Maximum current through relay contacts 1000 mA
Voice interface Yes
WEB interface Yes
1-Wire interface Yes
Operating temperature range from -30 to +55 ° С
Frequency bands of the GSM modem 800, 900, 1800, 1900 MHz
GPRS data link Yes
BL-5C backup battery (optional) purchased separately
Time to reach operating mode no more than 50 sec
dimensions 77 x 86 x 33 mm
Weight 200 g
Body material Plastic

Equipment:

  • Thermostat (Main unit of the system) - 1 pc.
  • Fixing base - 1 pc.
  • Digital temperature sensor - 1 pc.
  • Terminal block (2 pcs.) - 1 pc.
  • AC adapter 220/12 V - 1 pc.
  • GSM antenna - 1 pc.

Buy GSM thermostat Zont H-1V- means to get ownership of a compact thermostat with its own SIM-card of any operator, which allows you to control the climate in the room from any phone (satellite, mobile or fixed connection), tablet or PC. Most boilers have jumper terminals (corresponding to the switched on boiler) for connecting a room thermostat. It is to these terminals that the Zont-H-1V modules are connected: this jumper is removed and the contacts of the Zont H relay are connected in its place.

The Micro Line company produces a model of the Zont H-1V thermostat, which is almost identical in functionality to the GSM Climate Zont H-1 thermostat, which differs only in different housings and some technical features:
- The relay in H-1V holds 220V, and in H-1 it is designed for 120V;
- Zont H-1V has a 220V-> 5V adapter for converting a high-voltage signal of a boiler alarm (available in Vaillant) into a low-voltage signal for the Zont input;
- The backup battery is built-in in the H-1V module, but in the H-1 it is not included in the basic configuration and can be purchased separately;
- The firmware of these modules is exactly the same, and the circuits are practically the same.
- Mounts on a DIN rail

Zont H1V will ensure economical consumption of fuel spent by the boiler for heating, will allow you to remotely set the temperature in the house and monitor the health of the heating boiler, as well as remotely control its operation!
Agree that manual control of heating devices is quite troublesome, and almost impossible at a distance. With the Zont H 1V unit, remote control of the heating system is not only possible, but also extremely simple and convenient! No matter how far from home you are, it is enough to call or send a command from a mobile phone or via the Internet to change the mode of the heating boiler and ensure a comfortable temperature in the house. Convenient, isn't it?

New opportunities!

Additional functions of the device allow you not only to save heating costs and monitor the operation of the heating boiler, but also to monitor the safety of the facility! The user can connect additional sensors, for example, motion, disconnection, water leakage, gas leakage, fire and smoke detectors, etc. Information is transmitted via mobile communication channels and the Internet.

Features of the Zont H-1V thermostat

Supports various pre-set temperature modes:
Economy - economical fixed temperature.
Comfort - a comfortable fixed temperature (usually a few degrees higher than the economical one).
Schedule - maintaining the set temperature according to the schedule.
Off - anti-freeze mode
Alarm - thermostat operating mode with a faulty temperature sensor.

The module will only call the owner's phone or the trusted numbers assigned by him, warning him about any changes or emergencies. Accordingly, Zont h-1v can receive commands only from the owner or from "their" phones. Unauthorized access is absolutely excluded - even if someone dialed the number by mistake, the device will ask for a password that only the owner and, for example, other family members or trusted persons, know. In addition to SMS control, it is possible to control it via the voice menu.
In fact, the GSM Zont H-1V module plays the role of your personal assistant - you called it, gave the command, for example, to heat it up in advance, and the whole family, as a result, will come to a warm and cozy home. Or vice versa: they forgot to turn down the power when leaving for work in the morning - no question, you can do it right from work, via the Internet.

Unlike competitors, the temperature cannot be controlled from the front panel, and all monitoring and control operations are performed using either a personal computer or mobile devices: a smartphone or tablet. This allows the owner to control the situation wherever he is, while significantly reducing the cost of equipment.
The Zont-H1V unit works even if the cellular connection is lost, for example, following a predetermined weekly schedule.
It is possible to use control commands in the form of SMS text and even using the voice menu.
A simple, functional and convenient graphical interface is used via a web browser or mobile application. All data is stored on the server, and at any time you can view convenient and visual graphs of the system, information messages or make the necessary settings.

New!

Weather-dependent automation - energy-efficient regulation of heating taking into account changes in outdoor temperature (the function is available for modules with firmware version 122: 74 and higher)

How does the Zont H1V thermostat control the boiler?

The thermostat measures the room temperature and turns on or off the output relay, controlling the boiler in heating mode so that the indoor temperature matches the set value.
It monitors the temperature in the house and outside, the supply voltage, the technical condition of the boiler and signals in the event of an emergency or a power outage. If the values ​​deviate from the specified ones, he informs the owner in any pre-selected way: by call, SMS message or notification via the Internet.

To use the Internet service, you do not need to install additional software, work is carried out using any modern WEB browser. Access to the Internet service is carried out through a personal page on the server zont-online.ru
From your personal account on the Internet service zont-online.ru, you must set the values ​​of the desired indoor temperature, as well as threshold levels for generating alarm messages when the temperature deviates by a critical (emergency) value.
The unit analyzes temperature changes inside the room using its own remote temperature sensor. Depending on the measurements made, it turns on or off the output relay, which controls the boiler operation in heating mode so that the indoor temperature corresponds to the value of the preset operating mode.
In the event of a boiler malfunction, the system will immediately notify the owner of this event, thus avoiding trouble.

Inputs, outputs and connected equipment

Thermal sensors (wired)
It is connected to 4 and 6 contacts of the thermostat in accordance with the proposed diagram. Up to 10 pcs can be connected at the same time. The distance of the latter in the loop is no more than 100 m. Long branches from the main loop can lead to inoperability of all sensors.
Boiler control output
Contacts 1, 2 and 3 of the thermostat are intended for connection to the boiler. Contact # 1 is common (O), contact # 2 is normally closed (NC) and contact # 3 (NO) is normally open. The device is connected to the boiler contacts intended for connecting a room thermostat.
GSM antenna
It is connected to a separate input and is located in the room in such a way as to ensure the most stable reception of the GSM signal.
Main power supply + 12V
From a 220V network through a power supply unit (220 / 12V network adapter) from the delivery set.
Backup power + 3.7V
Built-in Li-ion battery.
Entrance 1 Analog input - contact # 5.
Designed to connect: or security sensors; or signal "Boiler alarm"; or room thermostat
Entrance 2 Digital input - contact # 8.
Designed to connect: or security sensors; or signal "Boiler alarm"; or room thermostat; or the OpenTherm interface and the ML-489 radio module.
Important!
Signals from an external room thermostat or "Boiler alarm" signals must not be connected to both inputs at the same time.
Can be simultaneously connected to Input 2 OpenTherm Interface and ML-489 Radio Module

Functionality of GSM thermostat Zont H-1V

Remote control of the boiler operation can be carried out:
- SMS commands;
- when dialing a SIM card number using the voice menu;
- via the Internet (WEB-interface and mobile applications for Android and for devices based on iOS).

Convenient and simple WEB-interface with the following capabilities:
- displaying the current state of the boiler and room temperature;
- boiler operation control;
- monitoring of temperatures (inside, outside the room, heat carrier) for any selected period of time;
- programming the boiler operation according to the schedule;
- notifications about activation of additional sensors.

Various event notifications:
- when the measured temperature deviates from the preset threshold values;
- about a boiler failure (provided that the thermostat is connected to the emergency output of the boiler);
- about the malfunction of the temperature sensor and the transition of the thermostat to emergency operation mode;
- about the loss or restoration of power supply, while a backup battery is required;

The event log
- a diary of measured temperatures for any period without a limitation period;
- date and time of the boiler failure detection;
- date and time of change of the boiler and thermostat operating mode;
- a list of executed control commands via the voice menu, sent by SMS, software updates;
- date and time of loss or restoration of power supply.

Signaling about the status of additional sensors connected to the "Alarm" input of the thermostat;
Memorizing events:
- readings of the temperature sensor;
- date and time of boiler failure;
- changes in operating modes;
- voice menu commands
- SMS commands;
- software updates (software);
- power on / off.
Update the current version of the unit's firmware without shutting it down and dismantling it from the user's personal account.

Zont H1V thermostat connection diagrams

Zont H-1V delivery set

Base unit: 1 pc.
External GSM antenna: 1 pc.
Temperature sensor (digital, wired): 1 pc.
Power supply unit (mains adapter) 220V / 12V: 1 pc.
Boiler alarm converter 220 / 5V: 1 pc.
Operation manual: 1 piece

Thermostat packaging

Technical characteristics of GSM thermostat Zont H-1V

Reference: ML13213
Manufacturer: MicroLine (commissioned by Evan)
Supply voltage: 10-28V
Maximum current consumption: 150 mA
Number of inputs: 2
Number of outputs (Type - dry contact, make / break): 1
Type of connected wired temperature sensors: DS 18S20
Type of connected radio thermal sensors: ML-703
Total number of simultaneously connected temperature sensors (wired and radio): 10
Maximum permissible length of the loop with temperature sensors: 100 m
Maximum current through relay contacts: 1000 mA
Maximum voltage of switched relay contacts: ~ 220 V, = 24 V
Voice interface: yes
WEB interface: yes
1-Wire interface: yes
Operating temperature range: from -30 to +55 ° С
Frequency bands of GSM-modem: 800, 900, 1800, 1900 MHz
Data channel: GPRS
GSM antenna: external
Internal non-volatile memory: yes
Back-up power supply: built-in Li-ion battery 103450-RSV-LD 2000 mAh
Time to reach operating mode: no more than 50 sec
Average service life: 7 years
Overall dimensions, mm: 90 x 50 x 55
Weight, no more: 0.200 kg
Enclosure: plastic DIN rail
Additional compatible equipment Zont: ML-489, ML-703, Zont Home, OpenTherm interface, Astra-9, Astra 512, Astra C, IO 102-16 / 2, Astra 361, ML-711, ML-712

GSM-Climate ZONT H-1 - remote control unit for heating boiler

  • Controlling an electric or gas boiler from the phone and via the Internet;
  • Notification of triggered security sensors (GSM-alarm);
  • Installation in a convenient place;
  • Controls the temperature in the house;
  • Saves resources for heating;
  • Maintains a comfortable temperature regime;
  • Warns about boiler failure;
  • Informs about entering the premises;
  • The maximum number of sensors is 5;
  • Recommended for self-installation.

Among other things, Micro Line has developed applications for Android and iOS, through which you can control the heating boiler from anywhere in the world.

An intelligent GSM thermostat will control your boiler so that it will heat your house only when it is really needed, maintaining a comfortable temperature in the house according to an individual schedule.

Going into the application, you can not only find out the temperature in the room, but also set the boiler to preset modes, turn it on on schedule, or simply turn off the boiler.

Attention! For the correct operation of the GSM-module in the territory of the Autonomous Republic of Crimea, a SIM-card of the mobile operator "Volna mobile" is required.
Today, Volna Mobile provides mobile data services in 2G, 3G, 4G standards throughout the Republic of Crimea and Sevastopol.

Control comfort from your phone, tablet or computer

ZONT H-1 is a room thermostat with its own SIM card to be connected to a heating boiler. Commands to it can be transmitted from any phone, tablet or PC.

For the convenience of work, there are free applications for the phone and a personal account on the site. To protect against unauthorized access, the entrance to your personal account is password protected.

Individual setting of operating modes

Comfortable temperature is different for everyone. Some love the tropical heat, others believe that 20-22 degrees is more than enough.

We have provided several modes of heating the house, so that you can choose the one you need at the moment with one movement.

In addition, you can easily create a weekly schedule for the heating boiler for the most optimal use of electricity or gas.

Safe boiler operation and comfortable temperature

The thermostat measures the room temperature and turns on or off the output relay, controlling the boiler operation so that the indoor temperature matches the set value.

It monitors the technical condition of the boiler and signals in the event of an emergency or power outage.

Alert system for all occasions

The thermostat controls the temperature in the house and outside, the supply voltage, the technical condition of the boiler and much more.

If the values ​​deviate from the specified ones, he informs you about this by calling or SMS-message.

10 temperature sensors for any purpose.

10 temperature sensors can be connected to the thermostat at the same time. These can be both wired and radio sensors.

The indications of the main are used to control the operation of the boiler. An additional one is assigned to it in reserve. If the main thermostat fails, it automatically switches to work by the backup sensor and the boiler control does not stop.

The readings of the remaining sensors are used for general monitoring of the heating system.

Easy installation, no special skills required

ZONT H-1 easily connects to an electric or gas boiler instead of a room thermostat. It inserts a SIM-card of any operator that provides stable reception, and supplies the power supply. You need to send an SMS from the owner's phone to the SIM-card number and "introduce" the device.

No need to pay to use the device

Pay only for the actual communication costs between you and the thermostat at the rates of the selected operator. And no monthly fee!

Which boilers can be installed with the ZONT thermostat

ZONT, ​​by its main purpose, is a simple room thermostat, but only made on a hardware platform using GSM / GPRS modem and WEB technology.

The principle of its operation and the method of connection to any gas or electric boiler is exactly the same as that of conventional thermostats. It connects to the connector for the room regulator and controls the boiler, maintaining the set temperature according to the readings of its temperature sensor. For this, the thermostat switches the boiler on or off by closing the contacts of its output relay.

Thus, if your boiler provides the ability to control commands from a room thermostat, then the ZONT thermostat can be used with it.

Supply voltage 10-28V
Maximum current consumption 150 mA
Number of analog inputs 1
Dry contact output (make / break) 1
Type of connected wired temperature sensors DS 18S20
Type of connected radio-temperature sensors ML-703
The total number of simultaneously connected temperature sensors 10
Maximum permissible length of a loop with temperature sensors 100 m
Maximum current through relay contacts 1000 mA
Maximum voltage of switched relay contacts ~ 120 V, = 24 V
Voice interface there is
WEB interface there is
1-Wire interface there is
Operating temperature range from -30 to +55 ° С
Frequency bands of the GSM modem 800, 900, 1800, 1900 MHz
Data transmission channel GPRS
GSM antenna external
Internal non-volatile memory there is
Built-in backup battery Li-ion / 1000 mA * H (option)
Time to reach operating mode no more than 50 sec
Average service life 7 years
dimensions 77 x 86 x 33 mm
Weight, no more 0.200 kg
Body material Plastic ABC

Equipment data