the Internet Windows Android

Castle of the Dark Forces ELC instruction. ELC Instructions - Electromagnetic Castle Controllers

information about delivery

Duration and delivery time

Order delivery in Moscow is carried out on 2 working day

Order delivery in St. Petersburg is carried out on 3 business dayAfter processing the order manager, the online store manager (order confirmation by phone).

- Delivery in Moscow within the Moscow Ring Road and St. Petersburg implemented monday through Saturdaybesides holidays, with 09:00 to 21:00.

- Delivery beyond the Moscow Ring Road implemented monday through Saturdayexcept holiday days

- Delivery B. suburb of St. Petersburg implemented monday through Saturdayexcept holiday days from 09.00 to 19.00 (without determining the minimum interval).

Shipping cost of goods ordered

- delivery in Moscow (within the Moscow Ring Road) subject to the cost order more than 2000 rubles implemented is free.

- delivery in Moscow (within the Moscow Ring Road) in the amount of less than 2000 rublesmake up 200 rubles.

- shipping cost in Moscow to areas outside the Moscow Ring Road (Zhulebino, Y. Butovo, Mitino, etc.), as well as in the Moscow region, within up to 10 km from Moscow Ring Road 250 rubles regardless of the order amount.

- the cost of delivery in the Moscow region is from 10 km to 30 km outside the Moscow Ring Road of MKAD 450 rubles regardless of the order amount.

- The shipping cost in St. Petersburg depends on the weight of the order. The minimum shipping cost is 300 rubles

- The cost of delivery by the suburb of St. Petersburg depends on the weight of the order. The minimum shipping cost is 450 rubles. The approximate shipping cost is calculated automatically when placing an order and is specified by the online store manager when the order is confirmed.

- To the cost of delivering orders, including those delivered free, weighing more than 10 kg Added 20 rubles for each subsequent kilogram. Specify the final shipping cost from the online store manager.

- please pay attention to customers from Moscow, Moscow region, St. Petersburg and the Leningrad region, which order weight from 30 kg and more delivered only before the entrance (without lifting on the floor).

Reserve of goods in the store

  • order with the condition for reserving goods in the retail store - 1 calendar day From the moment of receipt of the Email notice of the preparedness of the order to issue

Instructions for electromagnetic locks of the ELC series

ELC series controllers are designed to embed into electromagnetic locks ML-450, ML-194 chord or similar design.
- Can be used in conjunction with access control devices that do not have electronic keys reader.
- Different with high reliability, simplicity of installation and operation.
- work S. electronic keys Metak TM2002, TM2003 and DALLAS DS1990A.
- Memory capacity - 508 keys (to order - 2044 keys).
- Programmable lock opening time 0.5 ... 125 seconds with increments of 0.5 seconds.
- Ability to use a master key for quick login to programming mode.
- Modifications for electromagnetic and electromechanical locks.
- Light (LED) and sound signaling of the lock opening.
- Opening button from the room.
- Built-in guard timer and supply voltage monitor.
- supply voltage: 12 b alternating or DC.
- dimensions (without a LED) 36 x 54 x 17 mm.
- Operating range of ambient temperatures: 30 ... + 55 ° C
ELC series controllers can be supplied in electromagnetic castles ML-450.

Brief instruction manual
ELC series controllers

1. Programming "Master - Key"


c) turn on the power;
d) Wait for 4 audible signals, remove the jumper;
e) attach the key to the contact device - you will hear 3 signals;
The "master key" is programmed and the device has passed into the programming mode of subscriber keys.
2. Programming subscriber keys
a) Attach the "master key" to the contact device - you will hear 3 sound signals;
b) Alternately applying keys to the contact device, bring them in the memory of the ELC series controller. Recording each key is accompanied by one beep. If the key is defective or already in memory - the signal will not follow.
c) Exit the programming mode of subscriber keys is carried out by pressing the button. In this case, the device counts the duration of the button hold down the button is pressed with a discreteness of 0.5 seconds. Calculated memorization duration and is used in the future as the duration of the lock opening.
3. Programming Castle opening duration
a) Attach the "master key" to the contact device - you will hear 3 signals;
b) Press the output button. In this case, the device will calculate the duration of the button hold down the button with an accuracy of 0.5 seconds. Calculated duration is remembered and is used in the future as the duration of the opening of the lock.
4. Clearing key memory
a) Disable the power of the device;
b) Close the jumper on the printed circuit board;
c) turn on the power;
d) wait for 4 audible signals; Next will follow a decade-second pause and again will turn on the beep;
e) within 3 seconds after the start of the audio signal, remove the jumper;
f) waiting for the stopping of the audio signal again install the jumper;
g) After some pause (at this time, the memory is cleared) will be restarted. At the same time, since the jumper remained installed, the device will enter In the "master key" programming mode, and you will hear 4 signals (see clause 1). You can program the "Mother key" or turn off and turn on the power of the ELC series controller, if the "master key" remains the same.
Note:
"Master key" when cleaning memory persists;
If, after cleaning the memory (clause 4, g), you will hear a long (3 seconds) beep, then this indicates a malfunction of the memory microcircuit. Repeat cleaning. If the result is negative - replace the microcircuit 24c16;
If within 3 seconds after the start of the sound signal, the jumper will not be removed (clause 4, e), the ELC series controller will switch to the test mode - the cyclic power on / off of the electromagnetic lock with a period of 6 seconds (3 seconds turned on, 3 seconds - switched off);
If, after stopping the beep (p.4, f), the jumper will not be installed again, the device will switch to normal operation without cleaning the memory.

· Different with high reliability, ease of installation and operation.

· Work with electronic keys MetakTM.2002, TM2003. and Dallas. Ds.1990 A..

· Memory capacity - 508 keys (to order - 2044 key).

· Programmable castle opening time 0,5 125 Seconds in step 0,5 seconds.

· Ability to use a master key for quick login to programming mode.

· Modifications for electromagnetic and electromechanical locks.

· Light (LED) and audio signal opening of the lock.

· Opening button from the room.

· Built-in watchdog timer and supply voltage monitor.

· Supply voltage: 12 B. AC or DC.

· Overall dimensions (without LED) 36 x. 54 x. 17 mm.

· Operating range of ambient temperatures: 30 ... + 55 ° C

Controllers can be supplied as part of electromagnetic locks ML-450.

1. Programming "Master - Key"

a)Disable the power of the device;

b)

c)Turn on the power;

d)Wait for 4 audible signals, remove the jumper;

e)Attach the key to the contact device - you will hear 3 signals;

The master key "is programmed and the device has moved to the programming mode of subscriber keys.

2. Programming subscriber keys

a) Apply "Master Key" to the contact device - you will hear 3 beeps;

b) Alternately applying the keys to the contact device, bring them into the memory of the controller. Recording each key is accompanied by one beep. If the key is defective or already in memory - a signal will not follow.

c) Exit the programming mode of subscriber keys is carried out by pressing the button. In this case, the device calculates the duration of the button hold down to be pressed with discreteness. 0,5 seconds. Calculated memorization duration and is used later as.

3. Programming Castle opening duration

a) Apply "Master Key" to the contact device - you will hear 3 signals;

b) Press the output button. In this case, the device will calculate the duration of the button holding down the condition with the accuracy 0,5 seconds. Calculated duration is remembered and used in the future as duration of the opening of the castle.

4. Clearing the key memory

a)Disable the power of the device;

b)Close the jumper on the printed circuit board;

c)Turn on the power;

d)Wait for 4 audible signals; Next will follow a decade-second pause and again will turn on the beep;

e)For 3 seconds after the start of the audio signal, remove the jumper;

f)Waiting for the stopping of the beep again set the jumper;

g)After some pause (at this time, the memory is cleared) will be restarted. At the same time, since the jumper remains installed, the device will enter the programming mode "Master Key"And you will hear 4 signals (see clause 1). You can program "Mother Key" Or turn off and turn on the power of the device if "Master Key" It remains the same.

Note:

· "Master Key" When cleaning memory persists;

· If after cleaning the memory (clause 4, g) you will hear a long (3 seconds) beep, it indicates a malfunction of the memory chip. Repeat cleaning. If the result is negative - replace the microcircuit 24c16;

· If for 3 seconds after the start of the audio signal, the jumper will not be removed (clause 4, e), the device will switch to the test mode - the cyclic power on / off of the electromagnetic lock with a period of 6 seconds (3 seconds the lock is turned on, 3 seconds - disabled );

· If after stopping the audio signal (clause 4, f), the jumper will not be installed again, the device will switch to normal operation without cleaning the memory.

More information about Products of the company "Metak" can be obtained in the Sales Department