In this article, I will consider all installation options and which components must be installed for the correct work with the portal of the State Procurement. So what is the state procurement? This is the portal (website) for organizing web auctions (competitions, auctions). To work with this portal, you must have the following by:

  • Cryptopro - According to cryptochipal data. License to use the program should be purchased to your organization. By paid. Download Distribution version 3.6 can from our site or from the official site cryptopro.
  • Token - Key to work with the portal. Typically, such keys are named, issued by the user. For example, if you need to sign a document, Ivanov Ivan Ivanovich's token is inserted and signed by its name.
  • PkiClient. - Drivers for working with USB token. Drivers can be.
  • Root certificate of the Certification Center.Download .
  • Server certificate. Download
  • Plugin Sign For Internet Explorer browser. The plugin is necessary for the signature of the document. When you click on the Sign button, the plugin calls the software tied to the token. Download.
  • Microsoft. Net Framework. What exactly the version is not clear. In the case of Windows XP - 2.0, it is already built in Windows 7 and is in Windows components.Download .
  • Lkomponent. - It is also necessary for the signature. Download.
  • vcredist -Libraries necessary for work. Download for 64 bit windows version. Download for 32 bit.

After installing all components, we reboot and try to go to personal Area and sign the necessary document.

What to do in case of error: Cannot Sign Data. Error Description: The object does not support this property or method?

  1. First you need to check the items, are the components specified above. If everything is installed, check whether Lkomponent and the SIGN component set correctly installed correctly, since it is he who is responsible for checking the signature.
  2. If you use the operating system Windows 7. or higher, then start finding Internet Explorer. right-click from under the administrator.
  3. If you have a 64-bit operating system, then start the 32x batter Internet Explorer.

Attention! State portal works only in the browser Internet Explorer.

This article described that it was necessary to work on the portal simply and understandable, as in official instructionwhich you can download here - a lot of water and not necessary information. If you have helped me, please leave your thanks in the comments.

When working with multi-level software packages in which reporting or executing financial transactions in the form of tracking the status of accounts or online payments, it is often possible to meet the appearance of a software failure with issuing a notification that a subject does not support properties or SIGN method . What to do in such a situation, not everyone knows. Nevertheless, if you understand the essence of the problem, solutions to eliminate it will seem very simple.

The object does not support the properties or SIGN method: the essence of the problem

The essence of what is happening is that for confidential operations related to financial (and not only) reporting, special digital signatures are used to ensure security (SIGN CAB), which certify the authenticity and reliability of alleged actions.

The failure in the form of an error "The object does not support properties or the SIGN method" indicates that such a signature is unreliable (which is very infrequent) or requested electronic document or the resource on which it is located is blocked by the security system, or the refusal to access is associated with the current browser settings, or the system cannot perform special scripts required to open the document due to the lack of installed support.

These are the main causes of failure. On them will be focused. Viral impact for obvious reasons is not considered, since it is so clear that the user must monitor the system independently. This is not discussed.

Turn off the protection system

To troubleshoot the failure in the form of an error "The object does not support properties or SIGN method", the first thing should be briefly disabled a regular antivirus installed in the system. In any software product of this type, this feature is provided.

It is usually enough just to use the PCM menu (right mouse button) on the anti-virus icon in the system tray, in which it is enough to choose a shutdown of protection for 10 minutes. After that, you can see if the requested document will open.

Additionally, access can block their own firewall Windows. It should also be deactivated and check if access has appeared.

If, when performing such actions, the object "Object does not support Properties or Sign method" disappears, the site should be made to the anti-virus exception list and perform the same settings in the firewall, but already for the browser application used in the default system, indicating the full path to the executable program file.

Change the properties of the browser

As practice shows, in most cases such a failure is manifested exclusively in the "Native" browser of Internet Explorer Windows. If you look at the properties of the browser, in which most of the parameters are configured, it is not difficult to notice that the default level of protection corresponding to the value "above average" is set. And the use of this particular parameter in most cases is completely unreasonable.

In this situation, you can change the browser settings by setting the security level by a special slider (fader) to the "below average" position.

This costs to pay attention to the support of executable scenarios and the ActiveX elements for which the permissions must be enabled in the security section.

Note that if the system is available without a user's apple additional Services Mail.Ru, Odnoklassniki or something else like that, they should be deleted, but it is desirable to use that it is not their own section of Windows programs and components, but to apply special utilities with advanced features (Iobit Uninstaller, Revo Uninstaller and etc.)

We use another browser

If the actions from Internet Explorer did not give results, there is nothing easier than try to open the necessary document in another program.

Browsers are now a lot (Chrome, Firefox, Edge, Opera, etc.) which software product will be applied, not so important. If access is obtained at least in one of them, it will already say that not everything is in order with IE, and the problem is not in digital signature.

Clause cache and cookies

If the opening of the document is impossible and in this case, to start, go to the basic settings and completely remove the entire computer garbage in the form of cache, cookies and visiting history.

In this case, any program has a special menu that is responsible for the period set to clean. For loyalty, it is better to choose the parameter "over the entire period" or "from the beginning of visits".

Finally, you can produce full reset Settings to the original state (Reset function) with the removal of all the above items and saved user data.

We update the.Net Framework platform with manual registration of components

Another, perhaps, one of the main points is associated with the lack of, incorrect installation or obsolescence of the special platform .NET Framework, without which the execution of some scripts and executable web applets is impossible.

To install the update (which, by the way, even when the update is turned on, it is not always automatically installed) it is not always possible to contact the official resource of Microsoft Corporation and download the setting distribution from the downloads section, after which it is installed in manual mode.

In some cases, even after the end of the integration of the platform, it is not always possible to use it correctly. This may be related to the errors of the OS themselves, which only for known reasons themselves can block the registration of some dynamic libraries responsible for running the Java and Visual Basic scripts (jscript.dll and vbscript.dll).

In this case, you will need manual registration via the command line running with the administrator rights, which uses the REGSVR32 command, and the names of the necessary libraries are prescribed through the spaces, as shown in the image above. But provided that the OS itself is not observed, such actions may not be required.

When you try to log in to the VTB24 client-bank system on the appropriate site, the user may encounter an error "The object does not support the BrowseForfolder property or method." Typically, this problem occurs in a situation where the Browseforfolder script used by the VTB24 system to select the user's desired directory, does not work correctly, or conflict with other software components. In this material I will tell you what the problem "The object does not support the property or the Browseforfolder property", what is its causes, and how to fix the Browseforfolder error on your PC.

What was already mentioned above, the overall cause of the dysfunction is incorrect operation of the script (file-script) BrowseForfolder, created to implement the user selection by the user you need.

The concrete causes of the error "Browseforfolder" may be as follows ":

How to fix the error "The object does not support property or the BrowseForfolder method"

To solve the problem with Browseforfolder in VTB24, I recommend to do the following:

  1. Download and install the latest version on your computer. internet browser Explorer (version 11.0 and higher). At the same time, make sure the browser complies with the version of your operating system (). To learn the discharge of your OS, press the Win + Pause keys, and in the window that opens, check the "System Type" parameter;
  2. Run your browser on behalf of the administrator. Click on the browser icon on the desktop right-click, and select "Run on the administrator";

  3. Install the latest version on your computer.NET Framework;
  4. Install the module cryptographic protection "VTB 24". If, when an error occurs, the system will offer you in the browser to install "Cryptographic Protection VTB24" from "Step Up, Inc", click on "Set" (it is recommended to click on the arrow to "install" and select there "for all users) and confirm the installation .

  5. Overload the page and try to log in again. If necessary, confirm the operation of the newly installed module by clicking on the "Allow" button in the appropriate notification;
  6. Change browser security settings. Run the browser, click on the settings icon (right on the right), select "Browser Properties". In the window that opens, go to the "Security" deposit, and install the security slider to the lowest value. Then go to the "Privacy" tab and remove the checkbox from the "Enable blocking blocking blocking" option;

  7. Check ActiveX Work Settings in your browser. Re-select "Browser Properties", go to the Safety tab and select "Other". In the window that opens, find the "Allow ActiveX Approved Approved" parameter (usually located at the bottom), and set its value to "Allow";
  8. Delete incorrect library files. Navigate to the main folder of Windows, look for the following files in the System32 directories or Downloadd Program Files:
  • mesproax.dll
  • mespro.dll
  • mespro.sig
  • MessagePro Class.

When you find them, remove them, restart your computer, and again try to enter the VTB24 client-bank system;

Often, users face the problem of confirmation of personal data when online operations - Cannot. sign Data.. Error Description: The object does not support the SIGN property or method. For example, this error occurs on the web pages of official organizations or financial institutions: zakupki.gov.ru, bus.gov.ru, VTB 24, EIS. Specifically, this error appears when you try to establish the EDS or when confirming personal data.

Causes Sing Errors

Error message indicates problems with Sign.cab.. This component is used in the formation of the signature itself and is very important components. The same causes of the appearance of an error may be set. The source can serve: not file installed Sign.CAB, missing or outdated root certificates (cryptopro, contour) for the EDS, the incompatibility of the Windows discharge with the browser, the absence of a package .NET Framework and others.

Error: The object does not support the property or SIGN method

How to fix the error CANNOT SIGN DATA

To correct this failure on Windows 7/8/10, you should check or execute all the items that will be described below. We have collected all the most common decisions that are given on the official forums of state procurement, bus.gov.ru and other communities.

To begin with, check the work of the site on another browser. If you perform operations via a specialized application, then check the settings where you specify another browser output to the network.

Correctly reinstall the lanit

Many advise the first to reinstall the corresponding lines - sign.cab. It is better to download it from the resource at which it fails (contact the caliper) or from another popular source. Select the bit (x32, x64) corresponding to your system and browser (!), Which is very important to work in Internet Explorer. The discharge plays an important role. Further:


Also worth checking

Conclusion

Most often, the error "Object does not support property or SIGN method" is a consequence of inappropriate bit when installing software (luba, browser, certificates), so carefully redeemed to this point. In any case, if you do not cope with the error, it is worth contacting the resource caliper, but as practice shows, the answers are waiting there for a very long time.

Error: "Failed to download the Capicom.dll module" Error: "Capicom object is not installed"

Errors with http://sberbank-ast.ru at the entrance by electronic digital signature)

Solving these problems in 5 minutes. (Your attention is given two ways, manual and automatic.) If in an automatic decimony after installing the first component, the error is saved, use Method No. 2 on how to write issues in Camentaria.


Automatic registrationcapicom_ libraries 2.1.0.2Mandatory component for working with EDS Capicom_ 2.1.0.2_SDK. capicom_dc_sdk.zip.

If after installing the autolystalator, you still have a rash error using the Capicom.dll librariesyou need to delete previously installed libraries, go to the registry using the REGEDIT command and remove all the keys with the indexcapicom.dll. After that, restart the workstation and go to the Manual Library setting procedure below the described scheme. Actual library on January 10, 2012v2.1.0.2

To install Capicom.dll on Windows (XP), follow these steps:

Manual registration of the installation of the Capicom_ library 2.1.0.2download Archive capicom_-dll_v2.1.0.2.zip. Unpacking in C: \\ Windows \\ System32 \\ (Capicom.dll). After placing the library in the desired directory, execute in the Command Row C: \\ Windows \\ System32 \\ REGSVR32 Capicom.dll

For installationCapicom.dll on Windows Vista, Windows 7, Windows 8, Windows 8.1 Follow these steps:

1. Dock the file capicom_-dll_v2.1.0.2.zip.

2. Unpack the C: \\ Windows \\ SYSWOW64 directory

3. Register the DLL library for this command line (Start - Run) Enter: c: \\ Windows \\ SYSWOW64 \\ REGSVR32.EXE CAPICOM.DLL

4. To create the repository, download the CreateOP file

5. Unzip file createOp_capicom.zip. and copy files from the folder

6. Go to C: \\ Windows \\ syswow64 \\ ... And insert the copied files with the file replacement

7. Run the CreateOP.Bat file (if you do not display the ".bat" extension, then you need to start the file that is displayed as "MS-DOS batch file")

8. After starting the file, a window must appear, click on OK

9. In the next window, click OK

Be sure to everyone domain names With which you work through Capicom should be added to trusted components in the properties of the browser !!! If this is not done, the error: "Failed to load the Capicom.dll module" and the error: "Capicom object is not installed" may appear in no depending on the availability of Capicom in the system. !!!